Simulation of the combustion chamber of a pitotubular boiler using the ansys computer tool


Authors

DOI:

https://doi.org/10.22517/23447214.15841

Keywords:

Ansys, Mathematical model, Combustion chamber, Combustion

Abstract

This article analyzes the combustion reaction between the fuel (ACPM) and combustion (AIR) that occurs inside the combustion chamber of a pyrotubular boiler using Ansys® software and selecting the fluent method (CFD), being the indicated one To simulate fluids. A study of the behavior of the temperature and pressure through the total length of the combustion chamber and in turn the molar and mass fractions of the products resulting from the combustion. The results of the variables were compared with the approach of a mathematical model implemented in the simulink tool, taking into account the same conditions and the ACPM fuel.

Downloads

Download data is not yet available.

Author Biographies

Francys Marcel Rodriguez Jimenez, Universidad Francisco de Paula Santander

Ingeniera Industrial Estudiante de maestria en ingenieria mecanica

Andrea Del pilar Fabra Rivera, Universidad Francisco de Paula Santander

Ingenieria Industrial

Jose Ricardo Bermudez Santaella, Universidad Francisco de Paula Santander

DOCENTE

Downloads

Published

2017-12-30

How to Cite

Rodriguez Jimenez, F. M., Fabra Rivera, A. D. pilar, & Bermudez Santaella, J. R. (2017). Simulation of the combustion chamber of a pitotubular boiler using the ansys computer tool. Scientia Et Technica, 22(4), 302–307. https://doi.org/10.22517/23447214.15841

Issue

Section

Eléctrica