Simulation of the influence of STATCOM on power system losses
DOI:
https://doi.org/10.22517/23447214.25278Keywords:
Flexible AC transmission systems, power system modeling, power transmission, reactive power control, static VAr compensatorsAbstract
The supply of growing electricity demand is possible through continuous technological advances and the expansion of national and international electrical systems. This scenario could introduce voltage drops and consequent changes in the reactive power flow throughout the electrical network. In order to control these problems, various strategies have been developed as a solution to improve the transport and distribution of electrical energy. One of them is the Flexible Alternating Current Transmission System (FACTS), and more specifically the STATic synchronous COMpensator (STATCOM). This paper investigates the influence and effectiveness of STATCOM to mitigate the losses in the transmission lines and its impacts on bus voltage drops. The simulations are performed using the software DIgSILENT PowerFactory and the results showed that STATCOM reduces the power system losses in an interval of 23.86% until 32.86%, and in addition, the STATCOM decreases the annual energy cost by 7.82% in the implemented test case.
Downloads
References
[1].Kogan and D. Bondorevsky, “La infraestructura en el desarrollo de américa latina,” Economía y desarrollo, vol. 156, no. 1, pp. 168–186, 2016.
[2].S. Abhinav and B. C. Pal, Dynamic estimation and control of power systems. Academic Press, 2018.
[3] M. Eremia, C.-C. Liu, and A.-A. Edris, Advanced solutions in power systems: HVDC, FACTS, and Artificial Intelligence. John Wiley & Sons, 2016. DOI: https://doi.org/10.1002/9781119175391
[4] A. Pillay, S. P. Karthikeyan, and D. Kothari, “Congestion management in power systems–a review,” International Journal of Electrical Power & Energy Systems, vol. 70, pp. 83–90, 2015. DOI: https://doi.org/10.1016/j.ijepes.2015.01.022
[5] S.-H. Song, J.-U. Lim, and S.-I. Moon, “Installation and operation of facts devices for enhancing steady-state security,” Electric Power Systems Research, vol. 70, no. 1, pp. 7–15, 2004. DOI: https://doi.org/10.1016/j.epsr.2003.11.009.
[6] S. Rahimzadeh and M. T. Bina, “Looking for optimal number and placement of facts devices to manage the transmission congestion,” Energy conversion and management, vol. 52, no. 1, pp. 437–446, 2011. DOI: https://doi.org/10.1016/j.enconman.2010.07.019
[7] S. Thangalakshmi and P. Valsalal, “Congestion management using hybrid fish bee optimization,” Journal of Theoretical & Applied Information Technology, vol. 58, no. 2, 2013.
[8] M. Mumtaz, S. I. Khan, W. A. Chaudhry, and Z. A. Khan, “Harmonic incursion at the point of common coupling due to small grid-connected power stations,” Journal of Electrical Systems and Information Technology, vol. 2, no. 3, pp. 368–377, 2015. DOI: https://doi.org/10.1016/j.jesit.2015.06.005
[9] M. Katira and K. Porate, “Computer simulation of 132/11 kv distribution substation using static var compensator (svc) for voltage enhancement a case study,” in 2009 Second International Conference on Emerging Trends in Engineering & Technology. IEEE, 2009, pp. 521–526. DOI: https://doi.org/10.1109/ICETET.2009.61
[10] S. Hameed and P. Garg, “Improvement of power system stability using genetically optimized svc controller,” International Journal of System Assurance Engineering and Management, vol. 5, no. 4, pp. 475–486, 2014. DOI: https://doi.org/10.1007/s13198-014-0233-6
[11] A. Sode-Yome, N. Mithulananthan, and K. Y. Lee, “Static voltage stability margin enhancement using statcom, tcsc and sssc,” in 2005 IEEE/PES Transmission & Distribution Conference & Exposition: Asia and Pacific. IEEE, 2005, pp. 1–6. DOI: https://doi.org/10.1109/TDC.2005.1547141
[12] S. M. Sajjadi, M.-R. Haghifam, and J. Salehi, “Simultaneous placement of distributed generation and capacitors in distribution networks considering voltage stability index,” International Journal of Electrical Power & Energy Systems, vol. 46, pp. 366–375, 2013. DOI: https://doi.org/10.1016/j.ijepes.2012.10.027
[13] S. Sreedharan, T. Joseph, S. Joseph, C. V. Chandran, J. Vishnu, and V. Das, “Power system loading margin enhancement by optimal statcom integration-a case study,” Computers & Electrical Engineering, vol. 81, p. 106521, 2020. DOI: https://doi.org/10.1016/j.compeleceng.2019.106521
[14] S. Abd-Elazim and E. Ali, “Optimal location of statcom in multimachine power system for increasing loadability by cuckoo search algorithm,” International Journal of Electrical Power & Energy Systems, vol. 80, pp. 240–251, 2016. DOI: https://doi.org/10.1016/j.ijepes.2016.01.023
[15] A. S. Siddiqui and T. Deb, “Voltage stability improvement using statcom and svc,” International journal of computer applications, vol. 88, no. 14, 2014. DOI: https://doi.org/10.5120/15424-4070
[16] S. Ratra, R. Tiwari, and K. R. Niazi, “Voltage stability assessment in power systems using line voltage stability index,” Computers & Electrical Engineering, vol. 70, pp. 199–211, 2018. DOI: https://doi.org/10.1016/j.compeleceng.2017.12.046
[17] J. P. Rivera Barrera, “Modelamiento y simulación de dispositivos facts para estudios eléctricos de estado estable,” 2008.
[18] L. V. Agudelo Gallego and L. Ruíz Ochoa, “Identificación de las ventajas, las desventajas y las características de los sistemas de transmisión flexible (facts),” 2008.
[19] O. A. Morfín-Garduño, L. A. Zavala-Rubio, F. Ornelas-Téllez, and R. Ramírez-Betancour, “Compensación de potencia reactiva mediante el control robusto de un statcom en un sistema de potencia,” Ingeniería, investigación y tecnología, vol. 22, no. 3, pp. 0–0, 2021. DOI: https://doi.org/10.22201/fi.25940732e.2021.22.3.020
[20] Empresa de energía de Bogotá S.A.S. E.S.P Colombia, “Impacto del SVC tunal 230 kV en el sistema eléctrico de EEBEN 2015,” 2017. [Online]. Available: https://docplayer.es/114850732-Empresa-de-energia-de-bogota-s-a-e-s-p-colombia-impacto-del-svc-tunal-230-kv-en-el-sistema-electrico-de-eeb-2015-bogota-agosto-de-2017.html
[21] E. P. de Medellín (EPM), “Facts modulares tecnología de la transformación de la red,” 2021. [Online]. Available: https://www.epm.com.co/site/con-la-nueva-tecnologia-d-facts-epm-se-ubica-a-la-vanguardia-electrica-en-america-latina
[22] F. M. Gonzalez-Longatt and J. L. Rueda, PowerFactory applications for power system analysis. Springer, 2014. DOI: https://doi.org/10.1007/978-3-319-12958-7
Downloads
-
Vistas(Views): 778
- PDF Descargas(Downloads): 452
- HTML (Español (España)) Descargas(Downloads): 25
Published
How to Cite
Issue
Section
License
Copyright (c) 2023 Scientia et Technica

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
The undersigned authors declare that the article submitted to the journal Scientia et Technica is an original work and that all its content is free of third-party copyright restrictions or has the corresponding authorizations. Consequently, the authors assume responsibility for any litigation or claim related to intellectual property rights, releasing the Technological University of Pereira and the journal Scientia et Technica from any liability.
If the submitted work is accepted for publication, the authors retain copyright to the article and grant the journal Scientia et Technica the right of first publication, as well as a non-exclusive, perpetual license to reproduce, edit, distribute, display, and publicly communicate the article in any medium or format, including print, electronic, databases, repositories, the Internet, or other scientific dissemination systems. The authors agree that the article will be published in open access and distributed under the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License (CC BY-NC-SA 4.0).
The journal Scientia will respect in all cases the moral rights of the authors, in accordance with the provisions of article 30 of Law 23 of 1982 of the Republic of Colombia, recognizing the authorship of the work, the right to integrity and the right of disclosure, which are inalienable and non-waivable.